Power O2k-FluoRespirometer

An optional configuration as additional system for increasing output combined with the O2k-FluoRespirometer.

Product ID: 10013-01

The Power O2k-FluoRespirometer includes the O2k-Fluo Smart-Module, TIP2k and O2k-sV-Module, and supports all add-on O2k-Modules of the Oroboros O2k. It can be added to an existing Oroboros O2k of any O2k-Series. This application does not require an additional ISS-Integrated Suction System and O2k-Titration Set.

 

O2k-Applications:

  • oxygen consumption
  • H2O2 production
  • ATP production
  • Ca2+
  • mitochondrial membrane potential

Compare packages

Additional information

Oxygen

Respiration chambers with minimum oxygen diffusion
• High-resolution of oxygen flux: ±1 pmol O₂ ∙s⁻¹∙mL⁻¹ in normoxia to anoxia
• High-resolution of oxygen concentration: 5 nM
• Long-term stability and linearity of the polarographic oxygen sensor (OroboPOS)
• Barometric pressure transducer for accurate air calibration at any altitude

SUIT protocols

Standardized substrate-uncoupler-inhibitor-titration DL-Protocols
• Real-time monitoring of respiratory rates and states
• Multiple titrations within a single assay for in-depth analysis of mitochondrial fitness

MultiSensor

Additional parameters recorded real-time in combination with oxygen in the same chamber
• Automatic and documented calibration routines, instrumental background tests, and mitochondrial assays supported by DL-Protocols

Temperature

4 to 47 °C; stability ±0.002 °C

Thermostat

Peltier temperature control

Chamber

Material: Duran glass
Volume: 2 mL or 0.5 mL

Specialized DatLab Software

For use on a Windows PC connected to the O2k via a USB port

Max. power input

120 W

Current at 100-120 V

max. 1.0 A

Current at 220-240 V

max. 0.5 A

Power consumption

During standard operation (when block temperature is stable at 37 °C and ambient temperature of 22 °C) approx. 24 W

Lab space required

The O2k requires a minimum of lab space (0.5 m bench space) next to an external PC or laptop, with sufficient space for the ISS, Titration Set and handling.
For maximum signal stability and optimal temperature control, the O2k should be placed in a position in which it is not exposed to direct sunlight and sudden changes of room temperature. Keep the space on the table below the O2k bottom clear to prevent any interference of ventilation beneath the O2k-Main Unit.

Configuration

Power O2k-FluoRespirometer: Hardware and DatLab Software

Stainless steel housing
Peltier thermostat 4 to 47 °C; ±0.002 °C
Barometric pressure transducer
2 Amperometric oxygen channels
2 ISE sockets for ion sensitive electrodes
2 Sockets for optical signals or NO
2 OroboPOS polarographic oxygen sensors
2 Duran® glass chambers
2 PVDF stirrers, electromagnetic control
2 PEEK stoppers with O-ring
2 Blue POM chamber holders with O-ring and V-ring
2 Blue POM OroboPOS-holders
2 Smart Fluo-Sensors, green LED emission, photodiode and filters, excitation LED 525 nm, pre-calibrated intensity
2 Smart Fluo-Sensors, blue LED emission, photodiode and filters, excitation LED 465 nm, pre-calibrated intensity
3 Filter Sets (Mg green/Ca Green, Amplex® UltraRed, Safranin) consisting of LED filters and photodiode filters
Current DatLab version with free follow-up upgrades within the warranty period

Power O2k-FluoRespirometer: Accessories and Consumables

1 MiR05-Kit: Mitochondrial Respiration Medium. For a final volume of 250 mL
1 Pkg. OroboPOS-Seal Tip
2 Pkg. OroboPOS-Membranes
1 OroboPOS-Electrolyte Powder
1 OroboPOS-Mounting Tool
1 Polishing Cloth
1 Polishing Powder 0.3 μm
1 O2-Zero Powder
1 Forceps for membrane application
1 Pipette Plastic ungraded
1 Pkg. Conditioning cloths for stainless-steel housing

TIP2k-Module: add-on for two-channel operation with the O2k-FluoRespirometer with automatic control by DatLab of programmable titration regimes and feedback control

4 Micro-injection syringes, 200 mm3, 180 mm needle length, 0.12 mm inner Ø; fixed needles with rounded tip
1 Pkg. Needle Spacers, silicone stops (200/Pkg.) with mounting tool
1 TIP2k-Needle Safety Support with cable guide
1 Pkg. TIP2k-Filter Papers (10/Pkg.)

O2k-sV-Module: small chamber volume to reduce the sample amount needed for OXPHOS analysis and cellular/mitochondrial respiratory function

2 Duran® glass chambers, with smaller operation volume (V) of 0.5 mL
2 PVDF stirrers for small volume chambers, electromagnetic control
2 PEEK stoppers for small volume chambers with O-ring
2 Black POM chamber holders with O-ring and V-ring
2 Black POM OroboPOS-holders

 

Included extras

Packing, handling, worldwide shipping
Remote support from Oroboros experts
1 Installation and startup support session (to be used within the warranty period)
3-year warranty

All trademarks used are properties of their respective owners.